Low Cost Campbell Pressure Washers Bagged Vacuum Cleaner Purchase
600 Watt Low Voltage Transformer. 600 Watt Low Voltage Transformer, $149.99. 3 Way Socket Connection can be use for 60w or larger transformers, $11.99. 4 Way Socket Connection can be used ...
Monday, December 26, 2011
Wednesday, December 14, 2011
Thursday, December 8, 2011
Monday, November 28, 2011
- Simran Ar 2000 - Heavy Duty 2000 Watts Continuous Use Voltage Transformer Regulator / Stabilizer for Worldwide Use.
!: Best Buy - Simran Ar 2000 - Heavy Duty 2000 Watts Continuous Use Voltage Transformer Regulator / Stabilizer for Worldwide Use. This instant

Post Date : Nov 28, 2011 19:46:21 | Usually ships in 1-2 business days

Converts 110/120 V to 220/240 V OR converts 220/240 V to 110/120 V (switch is on back of unit) » On/Off switch with indicator lamp » Analog meter on front of unit shows exact output voltage » Voltage stabilizer good for countries with unstable voltage supply » 4 outlets on front of unit (outlets accept 3 or 2 prong US plugs and 2 prong Euro/Asian plugs) » Insulated power cord is hard wired with a European Shucko plug also good for Asian outlets » Heavy-duty metal casing and durable design» Comes with round and flat pin plugs for use in USA, Canada, and Mexico » Fuse protected. TRANSFORMER PURCHASE GUIDE:Remember to leave at least a 60%-70% slack for the transformer. For the TVs, the power surge margin is 5 times the wattage of the TV. Heating appliances, laser printers and power tools spike when you turn them on. For these products you need to buy a transformer that is at least 3 times the items capacity.
More Specification..!!
Sunday, November 20, 2011
Wednesday, November 16, 2011
Sunday, November 13, 2011
Tuesday, November 8, 2011
Sunday, October 30, 2011
Bipolar Tesla braid in action
Sunday, October 23, 2011
Wednesday, October 19, 2011
LiteFuze LR-5000 5000 Watt Heavy Duty Voltage Regulator w/ Voltage Converter Transformer - Step Up/Down 110/120/220/240V (Free Euro Plug) - Patented Universal Output Sockets
!: Promotion LiteFuze LR-5000 5000 Watt Heavy Duty Voltage Regulator w/ Voltage Converter Transformer - Step Up/Down 110/120/220/240V (Free Euro Plug) - Patented Universal Output Sockets purchase
Brand : LiteFuzeRate :

Price :
Post Date : Oct 19, 2011 19:48:09
Usually ships in 1-2 business days

Up to 5000 Watt Maximum Capacity Heavy-Duty Voltage Regulator Heavy duty for continuous use On/Off Power Switch LED Indicator for Power Source Single phase Dual Voltage Step Up or Step Down functionality Input: 110V/120V or 220V/230V/240V (Single Phase) Output 110V/120V or 220V/230V/240V (Single Phase) Input Selection in the rear of the converter Dimensions: 12"x11.5"x7" * Weight: 34 lbs. Five outlets for output in the front - 2 sockets - Universal outlet (220/240v single phase) - 3 sockets - Grounded USA (110/120v) Fuse protected with Built in Circuit Breaker NOTE: We recommend to use a Voltage Converter / Transformer that's max watts is at least 50% higher than your appliance. Some appliances such as Power tools, Motors, Laser printers and TVs require 2-3 times more watts at start up than the printed rating. We do not recommend voltage converters to use with coffee makers, hair dryers, microwave ovens and other heat producing appliances. US 220V products are two-phase 220V products and are not designed for use with this item.
Best Prices Mouse Trap Glue Comparison Gardenia Passion Perfume Learn Deer Baby Bedding
Sunday, April 10, 2011
Monday, March 28, 2011
Testing a Transformer - How To Accurately Test A Transformer
There is two types of transformers in the market- linear transformer and switch mode power transformer. The transformers found is different. Sometimes it is just referred as ac transformer. Linear transformer mostly used in radio, project kits, Vcd and etc while switch mode transformer can be found in Monitor, Tv, Fax and so on.
A transformer consists of two or more coils wound on the same core. For power transformers, the core material is usually iron. For a radio-frequency transformer, the core material is usually ferrite or air. The basic asset of a transformer is to convert Ac voltage. A transformer cannot convert direct current voltage. A step down transformer has a lower Ac yield voltage at its secondary winding than the Ac input voltage to its traditional winding. Conversely, a step up transformer has a higher secondary than traditional voltage. The transformer laminations or coating of shellac, enamel or varnish is to insulate adjacent turns from shorts in the middle of winding. I will not go too details about how transformer work and transformer calculation as you can read more details from most electrical and electronic transformers books.
How to test transformers: Transformer failures are relatively rare in most electronic equipment, compared with other Components. If too much current goes through a coil or winding, the winding heats up and can either open up completely, or the insulation in the middle of turns of wire can break down, causing the coil to be partly or fully shorted.
Just like a coil, you can check continuity of any traditional or secondary transformer winding. The actual value of Dc resistance you read is rather meaningless, but at least you will know either a winding is open. Checking linear transformer is quite right forward. Apply the ac voltage to the traditional winding and expect yield voltage at the secondary side. No or low yield voltage means the transformer winding has open or shorted winding. Look for any evidence of overheating, such as darkened or blackened areas or a burnt smell.
About how to test a power transformer-it is a little bit complicated. You cannot apply ac voltage to the equipment and expect the desire yield at the secondary side without associate to load otherwise over voltage will happen (because you have removed all the secondary load) and will blow the power section which consist of power fet, pwm ic and etc. Switch mode power supply are designed to run with load while linear transformer can be test without load.
The best way to test a switch mode power transformer is first take off it from the board. Check only the traditional winding as secondary winding failures are exceedingly rare. How do we know which one is the traditional winding? Trace from the big filter cap the certain pin to see where the circuit goes. It will go to one of the pin of the transformer. Then look for the power fet middle pin which is the Drain and it will lead to another pin of the transformer. This two pins is the traditional winding of the transformer. Checking the resistance of the traditional winding only can impart either it is open but it cannot check if it has developed a shorted winding. Only by using a ringer test you will know if it shorted or not. A shorted turn in the traditional winding can cause the power section to blow.
The cheapest ringer tester that i came across is Dick Smith Lopt Meter or flyback tester. Just associate the probes to the traditional winding and the ensue are instantly seen from the Led bar graph. 4-8 bar recount a good winding, 1-2 bar recount partial short and if the led goes off means there is a heavy short in the winding. Also checking the transformer it can be use to check B+ Coil, horizontal yoke coil and flyback traditional winding and ballast (choke).
The costly ringer tester is from sencore equipment. Sencore Lc102 and Lc103C Also checking capacitor it also have the capability to check all kind of winding. either it is a low voltage transformer, high voltage transformer, current transformer, pulse transformer, galvanic transformer, convention transformer this equipment will be able to check and test it.
If you do not wish to spend on this tester you may use a light bulb to check it. take off one of the traditional winding pin and associate a 60 watt light bulb. One end to the circuit while the other to the transformer pin. If the bulb light and didn't goes off hypothesize a shorted winding and if the light goes off, the winding is ok.
Transformer heal is not easy and it wish a good skill to do it. Most of the transformer repairer favorite to rewind bigger winding such as fan, car alternator and starter. Switch mode power transformer is a little bit difficult to rewind because of the small size and low price.
!: Solve Almond Milk Smoothie Recipes !: Omc Water Pump Fast
Wednesday, March 16, 2011
Model MT-600RP 600 Watt Multi-Tap Transformer with Remote Photocell Module.
!: Best Buy Model MT-600RP 600 Watt Multi-Tap Transformer with Remote Photocell Module. discount

Post Date : Mar 16, 2011 11:32:29 | Usually ships in 1-2 business days

Our next generation of transformers includes many new features while maintaining the quality and reliability that Vista is known for. Some of the features include an extra large terminal strip for multiple low voltage cable connections and a 120 Volt terminal strip for easy hardwiring. A custom designed weathertight clear coated stainless steel casing seals components from moisture and debris. Take apart stainless steel hinges allow for easy door removal and greater access during installation. All Vista Transformers come with a lifetime warranty.
- Low Voltge Lighting Trnsmer
- Large Terminal Strip with Multi-Tap Terminals from 11-15 Volt Taps
- True Constant Voltage at all Terminals
- Remote Photocell Module
- Lifetime Warranty
!: Dragonfly Tiffany Table Lamp Answer !: New Frye Deborah Boot
Sunday, March 13, 2011
50-WATT International Converter
!: Best Prices 50-WATT International Converter Order Now
Brand : JensenRate :

Price : $5.15
Post Date : Mar 14, 2011 00:16:46
Usually ships in 1-2 business days

Converts foreign voltage (220-240V AC) to U.S. voltage (110-120V AC)For use with electronic razors radios portable tape players and similar devices
!: Learn How Homelite Electric Pole Chain Saw !: Black And Decker Electric Hedge Trimmer Coupon !: Frye Tall Boots Best